GRAETZ Electronic Personal Dosemeter ED 150
with doserate indication and alarm functions
- PTB-approved dosemeter for measuring gamma- and X-rays
- measuring size: personal dose equivalent Hp (10)
- detector: built-in GM-tube
- digital indication of measured values on LC-display
- dose indication range with floating point
- doserate indication upon keystroke
- high measuring accuracy
- reliable measurement of radiation in a solid angle of 180° in front of the user
- excellent reading of the display by a special shaped housing
- switchable acoustic single-pulse indication
- 4 dose alarm thresholds
- 4 doserate alarm thresholds
- menu-driven operator-guidance
- optical interface
- storage of dose value and set parameters also during battery replacement
- continuous self testing and monitoring to ensure high reliability
- small and handy compact housing made of high impact-proof plastic, easy to decontaminate, watertight up to 0,5 m depth, (acc. to IP67)
- power supply by 3 Lady cells LR1, 1,5V
- battery life approx. 1 year at ambient background radiation
- when used together with the readout unit EDAG 02 also usable as system dosemeter
Technical Data
Dose indication range | 0,1 µSv ≤ Hp(10) ≤ 10 Sv |
PTB-approved dose measuring range | 10 µSv ≤ Hp (10) ≤ 1 Sv |
Doserate indication range | 0,1 µSv/h – 1,5 Sv/h |
Energy range | 55 keV – 3 MeV |
Dose alarm thresholds | 4 pre-set values in the range of 1 µSv up to 10 Sv |
Doserate alarm thresholds | 4 pre-set values in the range of 1 µSv/h – 1,5 Sv/h |
Temperature range | -20 °C up to + 60 °C |
Dimensions | (136x40x17) mm |
Weight | approx. 160 g |
PTB – Approval No. | 23.52 / 04.01 |
German Fire Brigades Approval No. | DW/FW/IdF 040411 |
Readout unit EDAG 02 for ED 150
The ED 150 can be either used as „stand alone“ dosemeter or together with the readout unit EDAG 02 as system dosemeter, too.
Via the RS 232 interface, the EDAG 02 has to be connected with a computer. The software is Windows compatible and serves for reading out measured data from the ED 150 (e. g. dose values) respectively for programming certain functions of the ED 150 (e. g. alarm thresholds, personnel numbers) and to represent these data graphically or in tabular form. All dose data can be processed with MS-Access.
The communication between the ED 150 and the readout unit is effected by the optical interface of the ED 150.