Bruker Daltonics
Bruker
Search

Search for literature

Login here!

Please state your username and your password below, in order to login to our user-system.

SVG 2

The new generation of nuclear radiation detectors

The SVG 2 is a hand-held, ruggedized micro-processor controlled radiation detector, based on state-of-the-art semiconductor technology. Equipped with integrated sensors for gamma and neutron radiation detection, an internal personal dosimeter, and an external a/b - g probe in the basic set.

Key features

  • Low weight and easy to handle design
  • Reduced power consumption
  • Measurement of g dose rate and dose
  • Adjustable alarm thresholds for all modes
  • Internal dose measurement of n and g radiation is performed with the shut off instrument
  • Data logger for 280 readings
  • Flexible use as hand-held or fixed radiation monitor
  • Additional hand held probes: a/b - g Probe, CP 170 contamination probe and the highly sensitive SP 45 for the detection of small amounts of g radiation
  • Ruggedized g - radiation probe for applications on board of ships
  • Set of vehicle g - probes according to NATO standard
  • Mounts for the base unit for onboard ship or vehicle use

Applications

The radiation survey meter SVG2 is in service with several armed forces worldwide. As part of NC monitoring systems the instrument is deployed in several ship and vehicle projects.

Technical Data

Basic Unit

  • Dimensions (WxHxL): 196x96x122 mm
  • Weight incl. batteries: 1.7 kg
  • Power Supply: 3x1.5 V (>90 hours of operation) and/or via vehicle (10-32 V DC)
  • Programmable thresholds for optical and acoustic alarm
  • EMP and TREE protected, water tight
  • Decontaminable by complete immersion
  • Measurement ranges:
    g-radiation: 70 keV...1.5 MeV
    g-dose rate: 0.5 µGy/h... 2000 cGy/h
    g-dose: 0-2000 cGy

Internal dosimeter

  • Dimensions (WxHxL): 196x96x122 mm
  • Measurement ranges:
    g-radiation: 0.1...3 MeV
    g- and n-dose: 0 cGy...2000 cGy (also measured when the instrument is shut off)
  • Power Supply: 3x1.5 V (>90 hours of operation) and/or via vehicle (10-32 V DC)
  • Programmable thresholds for optical and acoustic alarm
  • EMP and TREE protected, water tight
  • Decontaminable by complete immersion


External a/b-g-probe

  • Dimensions (WxHxL): 196x96x122 mm
  • For measurement of surface activity and contamination of liquids. Separate and combined measurement of a-, b- and g-radiation
  • Measurement ranges:
    a-, b-radiation: 0...350 kCps (0...550 kBq/cm2)
    g-radiation: 70 keV...1.5 MeV
    g-dose rate: 0.5 µGy/h... 200 cGy/h

External vehicle g-probes

  • Measurement ranges same as base unit

Probe for naval environments

  • Dimension: 140 x 159 mm (Ø x H)
  • g-dose rate: 1.0 mGy/h - 20 Gy/h
SP 45 Probe
CP 170 Probe

CP 170 contamination probe

 

Detector:

Large area and thin layer plastic scintillation detector with ZnS-coating for a, b and g measurements with integrated photomultiplier, high voltage power supply and pulse processing.

Measuring channels:

a-channel and b/g-Channel

Result display on the SVG2:

Optional in cps or for special nuclides in Bq/cm²

Dimensions:

ca. 280 x 125 x 135 mm
(L (with handle) x W x H)

Weight:

ca. 700 g

Casing:

Ergonomic plastic casing

Detector - Type:

Zincsulfide coated plastic scintillator with magnetic shielded photomultiplier

Detector - Size:

170 x 100 x 1 mm³

Detector - Protective grid:

Honeycomb grid 0.5 mm thick with 87,5 % transparency
General transparency with outer frame 83 %

Detector - Protective foil:

Thickness: 3µm
Both sides coated with aluminium
Two-part fixed on a frame

Usage range - Air pressure:

100-1300 hPa, (influence can be ignored)

Usage range - Temperature:

operation: -10 °C ... 40 °C, non condensing
storage: -20 °C ... 50 °C

Detector voltage:

Up to 1500 Volt

SP45 highly sensitive scintillation probe

 

Detector type:

CsI Scintillation detector for the measurement of gamma radiation

Detector size:

1,5" x 2"

Result display on the SVG2:

Optional in cps or µGy/h

Dimensions:

Length: 180 mm
Diameter: 45 mm

Weight:

ca. 350 g

Casing:

Aluminium casing

Wall thickness in the detector region:

Front side: 0.2 mm
Face: 1.0 mm

Background counting rate:

at 60 nSv/h: 85 cps

Usage range:

Air pressure: 100-1300 hPa
Temperature: -20 °C ... 50 °C

 
think forward