. .
Bruker Daltonics
Bruker
Search

Search for literature

Login here!

Please state your username and your password below, in order to login to our user-system.

PROTEINEER-LC

LC-MS/MS-based Proteomics Suite

Öffnet einen internen Link im aktuellen FensterWatch the IMSC 2006 presentation "ETD and beyond" in a 14 minute video.

For more quality data and more knowledge in LC-MALDI MS/MS, LC-ESI-MALDI MS/MS, 2D-LC-MS/MS and Quantitative Proteomics.

LC-MS/MS based analytical strategies are rapidly moving into focus for elucidating complex proteomics samples. They are used as complement to the classical gel-based approach. Mass spectrometric information is generated with online-ESI- and/or offline-MALDI-MS/MS, both technologies delivering complementary protein sequence data for maximum information depth.

Bruker Daltonics offers a comprehensive, integrated platform to support all major LC-based proteomics strategies: PROTEINEER-LC™!

The PROTEINEER-LC toolbox

Sample Preparation and LC Separation

  • All widely used CapLC and nanoLC systems supported by PROTEINEER fc™ MALDI Fraction Collector


Mass Spectrometry with

  • ultraflex III™ TOF/TOF
  • autoflex III™ TOF/TOF
  • HCT™ series
  • ESI-Ion Trap MS systems


Data Interpretation with

  • WARP-LC Protein Browser
  • LC Run Survey


Knowledge Generation with

  • ProteinScape™ Database System for Proteomics Project Management

Workflow Control

The WARP-LC™ software module supports various LC-based proteomics workflows and controls data acquisition throughout the analytical process. The intelligent precursor ion selection for MALDI MS/MS takes isotopic labelling or LC-ESI results into account. This strategy provides maximum information content while minimizing sample consumption and analysis time. Samples are tracked at any stage by Bruker Daltonics’ unique transponder technology.

click for larger image
click for larger image
click for larger image

Technical Specifications:

Target Applications

  • High-success protein identification from complex protein mixtures, starting with 1D- or 2D-LC separation
  • Detailed characterization of PTMs, polymorphisms, etc.
  • Quantitation by stable isotopic labeling experiments, such as ICAT™*
  • LC-ESI-MS/MS, LC-MALDI-MS/MS, and combined LC-ESI-MALDI strategies supported

LC and Sample Preparation

  • All widely used nanoLC and Capillary LC systems fully supported
  • PROTEINEER fc™ Fraction Collector for accurate preparation of AnchorChip™ MALDI targets (LC-MALDI- and LC-ESI-MALDI workflows)

Mass Spectrometry

High-performance ESI-ion trap MS/MS and MALDI-TOF/TOF technology from one vendor:

  • Ultra-fast LC-ESI-MS/MS with highest sensitivity and dynamic range
  • Advanced MALDI-TOF/TOF MS with AnchorChip technology for higher sequence coverages, search scores, and success rates of protein ID
  • MALDI targets in MTP format (384 and 1536)
  • Prespotted AnchorChip™ - disposable MALDI targets for elimination of cross contaminations and storage for re-analysis

Workflow Management

  • Complete software integration of all system components, including full sample tracking through transponder reading
  • WARP-LC™ software for LC-based proteomics workflow control
  • Intelligent result feedback for maximum sample readout at minimum time

Data Interpretation and Knowledge Generation

Comprehensive set of tools for validation and reporting of results:

  • LC Run Survey™ for quick evaluation of entire LC-MS/MS runs
  • WARP-LC Protein Browser to report identified proteins and peptides
  • BioTools™ software for automated and interactive interpretation of MS and MS/MS data, providing analysis tools for mutations, polymorphisms, and modifications, such as de novo sequencing
  • ProteinScape™ database solution for proteomics project management

For research use only. Not for use for diagnostic purposes.

*ICAT is a trademark of the University of Washington.

Related products

PROTEINEER fc

LC-MALDI Fraction Collector

Prespotted AnchorChip

Prespotted AnchorChip (PAC) targets dedicated for Proteomics

autoflex III, autoflex III TOF/TOF

High-productivity MALDI-TOF and TOF/TOF systems

ultraflex III, ultraflex III TOF/TOF

Ultimate performance MALDI-TOF and TOF/TOF systems

HCT

The next Generation High Capacity Trap

HCTultra

The ultra Performance High Capacity Trap

BioTools

Protein Data Analysis Package

ProteinScape

Database System for Proteomics Project Management

MALDI Matrices

MALDI Mass Calibration

MALDI Targets

Further Readings

Please enable cookies!

For research use only. Not for use in diagnostic procedures.

 
think forward