Language
SVG 2
The new generation of nuclear radiation detectors
The SVG 2 is a hand-held, ruggedized micro-processor controlled radiation detector, based on state-of-the-art semiconductor technology. Equipped with integrated sensors for gamma and neutron radiation detection, an internal personal dosimeter, and an external a/b - g probe in the basic set.
Key features
- Low weight and easy to handle design
- Reduced power consumption
- Measurement of g dose rate and dose
- Adjustable alarm thresholds for all modes
- Internal dose measurement of n and g radiation is performed with the shut off instrument
- Data logger for 280 readings
- Flexible use as hand-held or fixed radiation monitor
- Additional hand held probes: a/b - g Probe, CP 170 contamination probe and the highly sensitive SP 45 for the detection of small amounts of g radiation
- Ruggedized g - radiation probe for applications on board of ships
- Set of vehicle g - probes according to NATO standard
- Mounts for the base unit for onboard ship or vehicle use
Applications
The radiation survey meter SVG2 is in service with several armed forces worldwide. As part of NC monitoring systems the instrument is deployed in several ship and vehicle projects.
Technical Data
Basic Unit
- Dimensions (WxHxL): 196x96x122 mm
- Weight incl. batteries: 1.7 kg
- Power Supply: 3x1.5 V (>90 hours of operation) and/or via vehicle (10-32 V DC)
- Programmable thresholds for optical and acoustic alarm
- EMP and TREE protected, water tight
- Decontaminable by complete immersion
- Measurement ranges:
g-radiation: 70 keV...1.5 MeV
g-dose rate: 0.5 µGy/h... 2000 cGy/h
g-dose: 0-2000 cGy
Internal dosimeter
- Dimensions (WxHxL): 196x96x122 mm
- Measurement ranges:
g-radiation: 0.1...3 MeV
g- and n-dose: 0 cGy...2000 cGy (also measured when the instrument is shut off) - Power Supply: 3x1.5 V (>90 hours of operation) and/or via vehicle (10-32 V DC)
- Programmable thresholds for optical and acoustic alarm
- EMP and TREE protected, water tight
- Decontaminable by complete immersion
External a/b-g-probe
- Dimensions (WxHxL): 196x96x122 mm
- For measurement of surface activity and contamination of liquids. Separate and combined measurement of a-, b- and g-radiation
- Measurement ranges:
a-, b-radiation: 0...350 kCps (0...550 kBq/cm2)
g-radiation: 70 keV...1.5 MeV
g-dose rate: 0.5 µGy/h... 200 cGy/h
External vehicle g-probes
- Measurement ranges same as base unit
Probe for naval environments
- Dimension: 140 x 159 mm (Ø x H)
- g-dose rate: 1.0 mGy/h - 20 Gy/h

- SP 45 Probe

- CP 170 Probe
CP 170 contamination probe
Detector: | Large area and thin layer plastic scintillation detector with ZnS-coating for a, b and g measurements with integrated photomultiplier, high voltage power supply and pulse processing. |
Measuring channels: | a-channel and b/g-Channel |
Result display on the SVG2: | Optional in cps or for special nuclides in Bq/cm² |
Dimensions: | ca. 280 x 125 x 135 mm |
Weight: | ca. 700 g |
Casing: | Ergonomic plastic casing |
Detector - Type: | Zincsulfide coated plastic scintillator with magnetic shielded photomultiplier |
Detector - Size: | 170 x 100 x 1 mm³ |
Detector - Protective grid: | Honeycomb grid 0.5 mm thick with 87,5 % transparency |
Detector - Protective foil: | Thickness: 3µm |
Usage range - Air pressure: | 100-1300 hPa, (influence can be ignored) |
Usage range - Temperature: | operation: -10 °C ... 40 °C, non condensing |
Detector voltage: | Up to 1500 Volt |
SP45 highly sensitive scintillation probe
Detector type: | CsI Scintillation detector for the measurement of gamma radiation |
Detector size: | 1,5" x 2" |
Result display on the SVG2: | Optional in cps or µGy/h |
Dimensions: | Length: 180 mm |
Weight: | ca. 350 g |
Casing: | Aluminium casing |
Wall thickness in the detector region: | Front side: 0.2 mm |
Background counting rate: | at 60 nSv/h: 85 cps |
Usage range: | Air pressure: 100-1300 hPa |